Wire rope services

Wire rope inspection and condition assessment

Wire rope degrades from the inside out. We combine electromagnetic testing with detailed visual inspection so the condition of the whole rope, not just its surface, is on record.

Heavy steel wire rope coiled on a hoist drum

Scope of work

What a rope inspection covers

Scope is set with you before we mobilise, based on the rope type, its duty and the standard or manufacturer requirement you are working to.

  • Electromagnetic testing

    Non-destructive electromagnetic inspection along the full rope length to detect broken wires, corrosion and loss of metallic area that a visual pass cannot reach.

  • Detailed visual inspection

    Close visual examination of the rope surface, lay length, crown wear, deformation, lubrication condition and areas of concentrated bending.

  • Terminations and end fittings

    Assessment of splices, sockets, swaged fittings, clips and attachment hardware, including the transition zones where damage tends to concentrate.

  • Sheaves, drums and rope path

    Review of the components the rope runs on, since groove wear and misalignment often explain the damage found in the rope itself.

Where we inspect

Rope applications we work on

If your rope is not listed here, ask us — the method depends on rope construction, access and duty cycle rather than the industry name.

  • Aerial ropeway haul and track ropes
  • Mine hoist and shaft ropes
  • Crane hoisting and boom ropes
  • Winch, tow and drag lines
  • Guy lines and standing rigging
  • Elevator and material hoist ropes

Reporting

What you receive afterwards

Every inspection ends with a written report: the method used, the locations examined, the indications found and their position along the rope, and our assessment against the acceptance criteria in force.

Where we find something that needs action, we say so plainly and reference the criterion it fails. Where a rope is serviceable, the report records that too, so you have a documented baseline for the next interval.

Discuss an inspection programme